PCE Instruments PCE-CTI 10-ICA TRMS ammeter for measuring voltages up to 1500 V AC/DC and currents up to 1000 A AC/DC
(Incl. Tax: €520.57)
The PCE-CTI 10-ICA is a versatile TRMS ammeter designed for measuring voltages up to 1500 V AC/DC and currents up to 1000 A AC/DC. This device is ideal for both professional and DIY applications, providing accurate measurements for a wide range of electrical parameters. It features a clear display for easy reading and offers multiple measurement functions, ensuring user-friendly operation. With its robust design, the PCE-CTI 10-ICA is suitable for use in various challenging environments, making it a reliable tool for electricians and technicians alike.
The TRMS clamp meter with Bluetooth 4.0 interface is an advanced instrument for measuring electrical voltages and currents in industrial and plant applications, designed to ensure accuracy, versatility, and operational safety. With its wide measuring range of up to 1,500 V AC/DC and 1,000 A AC/DC, it is the ideal solution for diagnostics and maintenance of photovoltaic, hydroelectric, wind power systems, and fixed electrical machines. Current measurement is performed inductively: the conductor simply needs to be placed inside the clamp, allowing measurements without interrupting the power flow. This feature makes the device practical and safe, particularly useful for quickly checking individual photovoltaic strings and detecting possible faults or irregularities.
In addition to conventional voltage and current measurements, the TRMS clamp meter integrates advanced functions such as inrush current detection, essential for analyzing the high current peaks occurring during motor startup in complex systems like industrial ventilation or stadium lighting. These measurements are crucial for correctly dimensioning power lines, fuses, and protective devices. With its VFD (Variable Frequency Drive) mode, the instrument is also capable of measuring frequencies from 45 Hz to 1 kHz, making it suitable for installations that employ frequency converters.
Technical Data:
| DC voltage | |
| Measuring range | ±600.0 mV |
| Resolution | 0.1 mV |
| Accuracy | ±(0.8 % of measured value + 8 digits) |
| Measuring range | ±6.000 V |
| Resolution | 0.001 V |
| Accuracy | ±(0.5 % of measured value + 5 digits) |
| Measuring range | ±60.00 V |
| Resolution | 0.01 V |
| Accuracy | ±(0.5 % of measured value + 5 digits) |
| Measuring range | ± 600.0 V |
| Resolution | 0.1 V |
| Accuracy | ±(0.8 % of measured value + 5 digits) |
| Measuring range | ±1500 V |
| Resolution | 1 V |
| Accuracy | ±(0.8 % of measured value + 5 digits) |
| Input impedance: >10 MΩ; Overvoltage protection: 1500 VDC / 1000 VAC rms | |
| AC voltage | |
| Measuring range | 0.000 - 6.000 V |
| Resolution | 0.001 V |
| Accuracy | 50 - 60 Hz: ±(1.2 % of measured value + 5 digits) 61 - 1 kHz: ±(2.5 % of measured value + 5 digits) |
| Measuring range | 0.00 - 60.00 V |
| Resolution | 0.01 V |
| Accuracy | 50 - 60 Hz: ±(1.2 % of measured value + 5 digits) 61 - 1 kHz: ±(2.5 % of measured value + 5 digits) |
| Measuring range | 0.0 - 600.0 V |
| Resolution | 0.1 V |
| Accuracy | 50 - 60 Hz: ±(1.2 % of measured value + 5 digits) 61 - 1 kHz: ±(2.5 % of measured value + 5 digits) |
| Measuring range | 0 - 1500 V |
| Resolution | 1 V |
| Accuracy | 50 - 60 Hz: ±(1.2 % of measured value + 5 digits) 61 - 1 kHz: ±(2.5 % of measured value + 5 digits) |
| The accuracy relates to 10 - 100% of the respective measuring range and a sine wave input impedance: >9 MΩ; Overvoltage protection: 1000 V DC/AC RMS The accuracy of the "PEAK" function is: ±10 % of measured value The response time of the "PEAK" function is: 1 ms |
|
| AC voltage with low input impedance (LowZ) | |
| Measuring range | 0.000 - 6.000 V |
| Resolution | 0.001 V |
| Accuracy | ±(3.0 % of measured value + 40 digits) |
| Measuring range | 0.00 - 60.00 V |
| Resolution | 0.01 V |
| Accuracy | ±(3.0 % of measured value + 40 digits) |
| Measuring range | 0.0 - 300.0 V |
| Resolution | 0.1 V |
| Accuracy | ±(3.0 % of measured value + 40 digits) |
| Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS The accuracy relates to 10 - 100% of the respective measuring range and a sine wave |
|
| DC and AC voltage (50 - 1 kHz) | |
| Measuring range | 0.000 - 6.000 V |
| Resolution | 0.001 V |
| Accuracy | ±(2.5 % of measured value + 40 digits) |
| Measuring range | 0.00 - 60.00 V |
| Resolution | 0.01 V |
| Accuracy | ±(2.5 % of measured value + 40 digits) |
| Measuring range | 0.0 - 600.0 V |
| Resolution | 0.1 V |
| Accuracy | ±(2.5 % of measured value + 40 digits) |
| Measuring range | 0 - 1000 V |
| Resolution | 1 V |
| Accuracy | ±(2.5 % of measured value + 40 digits) |
| Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS | |
| DC and AC voltage with low input impedance (LowZ) | |
| Measuring range | 0.000 - 6.000 V |
| Resolution | 0.001 V |
| Accuracy | ±(3.5 % of measured value + 40 digits) |
| Measuring range | 0.00 - 60.00 V |
| Resolution | 0.01 V |
| Accuracy | ±(3.5 % of measured value + 40 digits) |
| Measuring range | 0.0 - 300.0 V |
| Resolution | 0.1 V |
| Accuracy | ±(3.5 % of measured value + 40 digits) |
| Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS | |
| Non-Contacting Voltage Verification (NCV) | |
| Detection range | 100 - 1000 AC/DC |
| Direct current | |
| Measuring range | ±60.00 A |
| Resolution | 0.01 A |
| Accuracy | ±(3.0 % of measured value + 8 digits) |
| Measuring range | ±600.0 A |
| Resolution | 0.1 A |
| Accuracy | ±(3.0 % of measured value + 8 digits) |
| Measuring range | ±1000 A |
| Resolution | 1 A |
| Accuracy | ±(3.0 % of measured value + 8 digits) |
| Overload protection: 1000 A AC/DC | |
| Alternating current (50 - 60 Hz) | |
| Measuring range | 0.00 - 60.00 A |
| Resolution | 0.01 A |
| Accuracy | ±(2.5 % of measured value + 5 digits) |
| Measuring range | 0.0 - 600.0 A |
| Resolution | 0.1 A |
| Accuracy | ±(2.5 % of measured value + 5 digits) |
| Measuring range | 0 - 1000 A |
| Resolution | 1 A |
| Accuracy | ±(2.5 % of measured value + 5 digits) |
| Overload protection: 1000 A AC/DC The accuracy relates to 10 - 100 % of the respective measuring range and a sine wave The inrush current measurement is for reference only |
|
| AC current measurement with flexible clamp meter (50 - 400 Hz) | |
| Measuring range | 0.00 - 30.00 A |
| Resolution | 0.01 A |
| Accuracy | ±(3.0 % of measured value + 5 digits) |
| Measuring range | 0.0 - 300.0 A |
| Resolution | 0.1 A |
| Accuracy | ±(3.0 % of measured value + 5 digits) |
| Measuring range | 0 - 3000 A |
| Resolution | 1 A |
| Accuracy | ±(3.0 % of measured value + 5 digits) |
| Overload protection: 1000 A AC/DC The accuracy relates to 10 - 100% of the respective measuring range and a sine wave |
|
| Resistance and continuity measurement | |
| Measuring range | 0.0 - 600.0 Ω |
| Resolution | 0.1 Ω |
| Accuracy | ±(1.0 % of measured value + 10 digits) |
| Measuring range | 0.000 - 6.000 kΩ |
| Resolution | 0.001 kΩ |
| Accuracy | ±(0.8 % of measured value + 5 digits) |
| Measuring range | 0.00 - 60.00 kΩ |
| Resolution | 0.01 kΩ |
| Accuracy | ±(0.8 % of measured value + 5 digits) |
| Measuring range | 0.0 - 600.0 kΩ |
| Resolution | 0.1 kΩ |
| Accuracy | ±(0.8 % of measured value + 5 digits) |
| Measuring range | 0.000 - 6.000 MΩ |
| Resolution | 0.001 MΩ |
| Accuracy | ±(0.8 % of measured value + 5 digits) |
| Measuring range | 0.00 - 60.00 MΩ |
| Resolution | 0.01 MΩ |
| Accuracy | ±(2.5 % of measured value + 10 digits) |
| Continuity test acoustic signal at: <50 Ω Overvoltage protection: 1000 V AC/DC |
|
| Frequency measurement | |
| Measuring range | 0.00 - 60.00 Hz |
| Resolution | 0.01 Hz |
| Accuracy | ±(0.2 % of measured value + 5 digits) |
| Measuring range | 0.0 - 600.0 Hz |
| Resolution | 0.1 Hz |
| Accuracy | ±(0.2 % of measured value + 5 digits) |
| Measuring range | 0.000 - 6.000 kHz |
| Resolution | 0.001 kHz |
| Accuracy | ±(0.2 % of measured value + 5 digits) |
| Measuring range | 0.00 - 60.00 kHz |
| Resolution | 0.01 kHz |
| Accuracy | ±(0.2 % of measured value + 5 digits) |
| Measuring range | 0.0 - 600.0 kHz |
| Resolution | 0.1 kHz |
| Accuracy | ±(0.2 % of measured value + 5 digits) |
| Measuring range | 0.000 - 6.000 MHz |
| Resolution | 0.001 MHz |
| Accuracy | ±(0.2 % of measured value + 5 digits) |
| Overvoltage protection: 1000 V AC/DC Sensitivity: >2 Vrms with a duty cycle between 20 - 80 % and a frequency of <100 kHz >5 Vrms with a duty cycle between 20 - 80 % and a frequency of >100 kHz |
|
| Duty cycle | |
| Measuring range | 10.0 - 90.0 % |
| Resolution | 0.1 % |
| Accuracy | ±(1.2 % of measured value + 8 digits) |
| Frequency range: 40 - 10 kHz; Pulse amplitude ±5 V with a duration between 100 µs - 100 mS |
|
| Capacity | |
| Measuring range | 0.00 - 60.00 nF |
| Resolution | 0.01 nF |
| Accuracy | ±(3.0 % of measured value + 20 digits) |
| Measuring range | 0.0 - 600.0 nF |
| Resolution | 0.1 nF |
| Accuracy | ±(3.0 % of measured value + 8 digits) |
| Measuring range | 0.000 - 6.000 µF |
| Resolution | 0.001 µF |
| Accuracy | ±(3.0 % of measured value + 8 digits) |
| Measuring range | 0.00 - 60.00 µF |
| Resolution | 0.01 µF |
| Accuracy | ±(3.0 % of measured value + 8 digits) |
| Measuring range | 0.0 - 600.0 nF |
| Resolution | 0.1 nF |
| Accuracy | ±(3.0 % of measured value + 8 digits) |
| Measuring range | 0 - 6000 µF |
| Resolution | 1 µF |
| Accuracy | ±(3.5 % of measured value + 20 digits) |
| Measuring range | 0.00 - 60.00 mF |
| Resolution | 0.01 mF |
| Accuracy | for reference only |
| Measuring range | 0.0 - 600.0 mF |
| Resolution | 0.1 mF |
| Accuracy | for reference only |
| Overvoltage protection: 1000 A AC/DC | |
| Temperature measurement thermocouple Type K (connection) | |
| Measuring range | -40.0 - 600.0 °C |
| Resolution | 0.1 °C |
| Accuracy | ±(1.5 % of measured value + 3 °C) |
| Measuring range | 600 - 1000 °C |
| Resolution | 1 °C |
| Accuracy | ±(1.5 % of measured value + 3 °C) |
| Measuring range | -40.0 - 600.0 °F |
| Resolution | 0.1 °F |
| Accuracy | ±(1.5 % of measured value + 5.4 °F) |
| Measuring range | 600 - 1800 °F |
| Resolution | 1 °F |
| Accuracy | ±(1.5 % of measured value + 5.4 °F) |
| Measuring range | 245.0 - 600.0 K |
| Resolution | 0.1 K |
| Accuracy | ±(1.5 % of measured value + 3 K) |
| Measuring range | 600 - 1273 K |
| Resolution | 1 K |
| Accuracy | ±(1.5 % of measured value + 3 K) |
| Overvoltage protection: 1000 A AC/DC | |
| Diode test | |
| Test current | <1.5 mA |
| Maximum voltage | 3.3 VDC |
| Further specifications | |
| Storage space | 16 groups with a total storage space of 100,000 measured values |
| Clamp diameter horizontal | 38 mm / 1.49" |
| Clamp diameter vertical | 63 mm / 2.48" |
| Clamp opening | 45 mm / 1.77" |
| Protection class | IP65 |
| Interface | Bluetooth 4.0 |
| Pollution degree | 2 |
| Insulation categories | CAT IV 600 V, CAT III 1000 V, CAT II 1500 V |
| Maximum working height | 2000 m / 6562 ft |
| Power supply battery | 7.4 V, 1200 mAh Li-ion battery |
| Power supply charger | Primary: 100 - 240 V AC, 50 - 60 Hz Secondary: 12 V DC, 2 A |
| Plug connection charger | Europa, USA, England, China |
| Battery status display | available |
| Automatic switch-off | switched off, 15, 30 or 60 minutes |
| Display | 2.36" TFT |
| Display frequency | 3 Hz |
| Reference conditions | 18 - 28 °C, 64 - 82 °F; <80 % RH, non-condensing |
| Dimensions | 275 x 100 x 45 mm / 10.8 x 3.9 x 1.7" |
| Weight | 481 g / 16.9 oz |
The device features a 2.36" TFT display for clear and immediate reading of measurement values and includes a Bluetooth 4.0 interface for connection to Android or iOS devices. Using the free “Meterbox Pro” app, users can view data in real time, store it, and perform detailed analyses afterwards, thus enhancing documentation and monitoring capabilities. The clamp meter also integrates a data logging function, storing up to 100,000 readings across 16 groups, each recorded with date and time, with the option to visualize results graphically directly on the instrument.
For applications requiring very high current measurements, the clamp meter can be expanded with an optional flexible current probe, capable of measuring up to 3,000 A AC. Its flexible design allows easy adaptation to various operational contexts, connecting to the voltage input of the device and converting the measured value into usable data displayed on screen.
The TRMS clamp meter comes with an ISO calibration certificate, ensuring metrological reliability and compliance with standards. In addition to current and voltage, it also offers extra features such as LowZ voltage measurement and temperature measurement, further extending its field of use. Thanks to its wide measuring range, advanced connectivity, robust design, and reliable performance, it is an indispensable tool for the monitoring, maintenance, and diagnostics of complex, high-power electrical installations, delivering precision and safety in every operation.
Features:
- Free app for Android and iOS
- Measuring range 0 - 1500 V AC/DC
- Data logging for up to 100,000 measured values
- Inrush current measurement
- Additionally with LowZ voltage measurement
- 2.36" TFT display
- With voltage and temperature measurement
- Incl. calibration certificate
Delivery scope:
1 x Clamp meter PCE-CTI 10-ICA
1 x Thermocouple Type-K with adapter
1 x Pair of measuring leads
1 x Carrying case
1 x Battery charging station
1 x Rechargeable battery
1 x Instruction manual
1 x ISO Calibration Certificate
N.B. Calibration certificates are issued specifically for the customer and are excluded from the right of return.
- EAN Code:
- 4250348729576
- Typology:
- Ammeter
- Brand:
- PCE INSTRUMENTS