PCE Instruments PCE-ET 5000 Portable VDE tester with memory, visual guidance, resistance measurement, lightning rod check and current, voltage and frequency check
(Incl. Tax: €3,408.07)
VDE Tester with memory, ideal for mobile use thanks to the battery. It performs resistance measurements, checks the protective conductor, and tests lightning rods. Equipped with a backlit display, it analyzes current, voltage, and stray frequency. The instrument measures resistance in 2 or 4 pole mode, including earth resistance, using the included stakes and a 20 m cable. It ensures safety by verifying the proper grounding of lightning rods in buildings such as schools, ensuring the effective grounding of lightning.
The VDE tester is a professional instrument for measuring resistance, verifying protection systems, and inspecting lightning protection devices. Thanks to its battery-powered portability, it is ideal for on-site inspections in industrial, civil, and infrastructural applications.
Technical specifications:
| 3-pole earth resistance | |
| Test voltage | 20, 48V AC |
| Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
| Short circuit current | 250-mA |
| Test time | 26 seconds |
| Probe resistance Rs | <100 kΩ |
| Auxiliary earth resistance Rh | <100 kΩ |
| Resolution | 0.001 Ω |
| Measuring range Re | 0.02 Ω - 300 kΩ |
| Accuracy | ± (5% + 10 digits) |
| Ust | < 24V |
| Fst | 16 - 400 Hz |
| The accuracy is ensured in an environment of 0 - 28°C / 32 - 82°F, < 80% RH (non-condensing). Response time < 15 seconds (Time required to reach the specified accuracy, after the start of the measurement with the average function switched off.) |
|
| 4-pole grounding resistor | |
| Test voltage | 20, 48V AC |
| Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
| Short circuit current | 250-mA |
| Test time | 30 seconds |
| Probe resistance Rs | < 100 kΩ |
| Auxiliary earth resistance Rh | < 100 kΩ |
| Resolution | 0.001 Ω |
| Measuring range Re | 0.02 Ω - 300 kΩ |
| Accuracy | ± (5% + 10 digits) |
| Ust | < 24V |
| Fst | 16 - 400 Hz |
| The accuracy is ensured in an environment of 0 - 28°C / 32 - 82°F, < 80% RH (non-condensing). Response time < 25 seconds (Time required to reach the specified accuracy, after the start of the measurement with the average function switched off.) |
|
| 3-pole earth resistance with current clamp | |
| Test voltage | 20, 48V AC |
| Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
| Short circuit current | 250-mA |
| Test time | 26 seconds |
| Probe resistance Rs | < 100 kΩ |
| Auxiliary earth resistance Rh | < 100 kΩ |
| Resolution | 0.001 Ω |
| Measuring range Re | 0.02 Ω - 20 kΩ |
| Accuracy | ± (5% + 10 digits) |
| Ust | < 24V |
| Fst | 16 - 400 Hz |
| The accuracy is ensured in an environment of 0 - 28°C / 32 - 82°F, < 80% RH (non-condensing). Response time < 25 seconds (Time required to reach the specified accuracy, after the measurement has started with the average function switched off.) If the current on the current probe is too low, the measurement can be aborted. |
|
| 4-pole earth resistance with current clamp | |
| Test voltage | 20, 48V AC |
| Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
| Short circuit current | 250-mA |
| Test time | 26 seconds |
| Probe resistance Rs | < 100 kΩ |
| Auxiliary earth resistance Rh | < 100 kΩ |
| Resolution | 0.001 Ω |
| Measuring range Re | 0.02 Ω - 20 kΩ |
| Accuracy | ± (5% + 10 digits) |
| Ust | < 24V |
| Fst | 16 - 400 Hz |
| The accuracy is ensured in an environment of 0 - 28°C / 32 - 82°F, < 80% RH (non-condensing). Response time < 25 seconds (Time required to reach the specified accuracy, after the measurement has started with the average function switched off.) If the current on the current probe is too low, the measurement can be aborted. |
|
| Grounding resistor only with current clamps | |
| Test voltage | 48V AC |
| Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
| Short circuit current | 250-mA |
| Test time | 26 seconds |
| Measuring range Re | 0.02 Ω - 150 Ω |
| Resolution | 0.001 Ω |
| Accuracy | ± (5% + 10 digits) |
| Ust | < 24V |
| Fst | 16 - 400 Hz |
| The accuracy is ensured in an environment of 0 - 28°C / 32 - 82°F, < 80% RH (non-condensing). Response time < 25 seconds (Time required to reach the specified accuracy, after the measurement has started with the average function switched off.) If the current on the current probe is too low, the measurement can be aborted. |
|
| Soil resistance (removal resistance) | |
| Test voltage | 20, 48V AC |
| Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
| Short circuit current | 250-mA |
| Test time | 26 seconds |
| Resolution | 0.001 Ω * m |
| Measuring range Re | 0.02 Ω - 1000 kΩ * m |
| Accuracy | ± (5% + 10 digits) |
| 2-pole resistance measurement (AC) | |
| Test voltage | 20V AC |
| Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
| Short circuit current | 250-mA |
| Test time | 26 seconds |
| Measuring range Re | 0.02 Ω - 300 kΩ |
| Resolution | 0.001 Ω |
| Accuracy | ± (5% + 10 digits) |
| Ust | < 24V |
| Fst | 16 - 400 Hz |
| 2-pole resistance measurement (DC) | |
| Test voltage | 20V DC |
| Short circuit current | 250-mA |
| Test time | 26 seconds |
| Measuring range Re | 0.02 - 3 kΩ |
| Resolution | 0.001 Ω |
| Accuracy | ± (5% + 10 digits) |
| Ust | < 3V |
| Fst | 16 - 400 Hz |
| 4-pole resistance measurement (DC) | |
| Test voltage | 20V DC |
| Short circuit current | 250-mA |
| Test time | 26 seconds |
| Measuring range Re | 0.02 Ω - 3 kΩ |
| Resolution | 0.001 Ω |
| Accuracy | ± (5% + 10 digits) |
| Ust | < 3V |
| Fst | 16 - 400 Hz |
| Line compensation | |
| Test voltage | 20, 48V AC |
| Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
| Short circuit current | 250-mA |
| Test time | 26 seconds |
| Resolution | 0.001 Ω |
| Measuring range Re | 0.02 Ω - 30 Ω |
| Accuracy | ± (3% + 10 digits) |
| Ust | < 24V |
| Fst | 16 - 400 Hz |
| Interference voltage | |
| Measuring range | ± 50V DC 1 - 50V AC |
| Resolution | 0.1V |
| Accuracy | ± (5% + 5 digits) |
| Interference current | |
| Measuring range | 20-mA - 2 A |
| Resolution | 1-mA |
| Accuracy | ± (5% + 5 digits) |
| Interference frequency | |
| Measuring range | 16 - 400 Hz |
| Resolution | 1 Hz |
| Accuracy | ± (1% + 10 digits) |
| Other specifications | |
| Data storage | 100 readings |
| Operating conditions | 0 - 40°C / 32 - 104°F, < 80% RH (non-condensing) |
| Charge ambient conditions to the battery | 10 - 40°C / 50 - 104°F, < 80% rh (non-condensing) |
| Storage conditions | -10 - 50°C / 50 - 122°F, < 90% rh (non-condensing) |
| Storage conditions for the battery | -20 - 30°C / -4 - 86°F, < 80% rh (non-condensing) |
| Storage height | < 12,000 m / 39,370 ft |
| Operating altitude | < 2,000 m / 6,561 ft |
| Clamp diameter | 51 mm |
| Display | Backlit LCD, 9,999 digits |
| Display measuring range exceeded | > LIMIT |
| Display below measuring range | - |
| Measuring frequency earthing resistance / leakage current | 1 Hz (If the average value function is activated: one value every four seconds) |
| Measuring frequency voltage measurement | 2 Hz |
| Measuring frequency interference voltage | 4 Hz |
| Measuring frequency interference frequency | 1 Hz |
| Measuring frequency interference current | 1 Hz |
| interfaces | Measuring connection: E, ES, S, H, pliers connection USB-B, charging connection |
| Power supply batteries | 6 x 1.5V D LR14 batteries |
| Power supply battery | 1 x 7.2V nickel-metal hydride battery pack |
| Power supply power supply | Primary: 100 - 240V, 50 - 60 Hz Secondary: 12V, 3A |
| Max. Power consumption with power supply | 15V A |
| Max. Power consumption with battery or rechargeable battery | 6V A |
| Running time in battery mode | About 5 hours |
| Running time in the battery | About 9 hours (without backlight) |
| Maximum input voltage | |
| Maximum input voltage relative to earth | 300V rms (CAT III) |
| Insulation thickness | 6880V AC: 15 seconds |
| Overvoltage protection | 250V AC between the connections |
| Dimensions | 260 x 125 x 280 mm / 10.2 x 4.9 x 11 in |
| Weight | About 2.5 kg / 5.5 lbs |
| Standardize | Safety: EN61010-1: 2001, EN61010-031: 2002 Pollution degree 2, CAT III 300V, EMC: EN61000-3-2: 2000, IEC61326-1: 1997 A |
Precise measurements are ensured in both 2-pole and 4-pole configurations, with the ability to test ground resistance using included stakes and a 20 m cable. Lightning rod testing is critical for sensitive buildings such as schools and hospitals, ensuring proper lightning discharge with optimal resistance values.
The integrated visual guide simplifies connections by highlighting the correct ports and triggering acoustic or visual alarms in case of errors. The device automatically blocks measurements until all cables are properly connected, minimizing incorrect readings. Stored data can be exported to a PC for further technical analysis.
In addition to resistance, the tester detects parasitic currents, stray voltages, and interference frequencies, making it suitable for advanced diagnostics in electrical systems and grounding installations. The large backlit display ensures readability even in low-light conditions, completing a rugged and functional design for professional use.
Features:
- Mobile use thanks to battery and batteries
- Data memory for later analysis on the PC
- Visual connection aid for easy operation
- Alarm in case of incorrect connection of the measuring line
- Direct and indirect resistance measurement
- Interference currents, interference voltages, frequencies
Delivery scope:
1 x PAT Tester PCE-ET 5000
4 x Crocodile clips
1 x Power supply
1 x USB cable
4 x Test cable
1 x Voltage terminal cable
1 x Power terminal cable
6 x 1.5V C batteries
2 x Current clamps
1 x Rechargeable Ni-MH battery
4 x Insert samples
1 x User manual
- EAN Code:
- 4250348719126
- Typology:
- Insulation tester
- Brand:
- PCE INSTRUMENTS