Language

Hello Guest!
Your Cart 0
€0.00

PCE Instruments PCE-GA 8 Gas detector with real-time data display and USB charging, for monitoring oxygen concentration in ambient air, measuring range from 0 to 30% Vol. oxygen

PCE Instruments PCE-GA 8 Gas detector with real-time data display and USB charging, for monitoring oxygen concentration in ambient air, measuring range from 0 to 30% Vol. oxygen

In stock
SKU
PCE-GA-8
€141.52
(Incl. Tax: €172.65)

PCE-GA 8 oxygen detector for environmental monitoring with O2 measurement from 0 to 30%, temperature control from -9 ... 55 °C and humidity from 0 ... 100%. Equipped with colour display showing %VOL, “GOOD” status, temperature, humidity, date, time and battery. Integrated 3000 mA lithium battery rechargeable via USB 5 V / 1 A, data saving and practical use for technical rooms, laboratories, offices and safety checks.

PCE Instruments PCE-GA 8 Gas detector with real-time data display and USB charging, for monitoring oxygen concentration in ambient air, measuring range from 0 to 30% Vol. oxygen

The PCE-GA 8 oxygen detector is a portable instrument designed to monitor oxygen concentration in the air while also providing temperature and humidity information in the same device. It is suitable for workplaces, technical rooms, laboratories, warehouses, offices, enclosed areas, production departments and locations where O2 control is important for safety, environmental quality and prevention of potentially critical conditions. Its compact structure and colour display make it practical for quick checks, periodic inspections and mobile monitoring.

The device measures oxygen in the 0 ... 30% range, a key parameter when checking whether an environment has an adequate oxygen concentration. The reading is displayed clearly with a large numerical value in %VOL. In the product image, the display shows 20.9 %VOL and “GOOD” status, together with a coloured reference bar that helps the operator immediately interpret the detected condition. This type of display is useful because it allows the user to quickly recognise whether the environment is in normal condition or requires attention.

In addition to O2 measurement, the PCE-GA 8 monitors temperature from -9 ... 55 °C and humidity from 0 ... 100%. These parameters complete environmental monitoring because temperature and humidity can influence comfort, equipment behaviour, environmental perception and operating conditions in technical or professional rooms. The display also shows temperature and humidity, allowing the operator to consult several values at the same time without separate instruments.

The colour display is one of the most important elements of the product. The main screen shows the oxygen value, quality status, reference bar, temperature, humidity, date, time and battery status. This layout makes the device intuitive even for users who do not need complex measurements but require an immediate and easy-to-read answer. In technical environments, where check time is often limited, a clear display reduces the risk of interpretation errors.

The PCE-GA 8 has front and side buttons for function management. The POWER button is located on the right side of the product: pressing it for 1 second switches the device on, while holding it for 2 seconds after start-up switches it off. After switching on, the display screens can be scrolled using the left and right buttons. The central button allows data to be saved and, when held for 3 seconds, provides access to system settings. This arrangement makes the device simple to use and suitable for frequent checks.

The ability to save data is useful when conditions measured at a specific moment need to be recorded. In professional use, saving a value can support periodic inspections, checks before room access, department monitoring, safety checks or comparisons between different areas of the same building. Data saving does not replace official recording procedures or fixed monitoring systems, but provides practical support for technical activities and operational inspections.

The integrated 3000 mA lithium battery enables mobile use and can be recharged via the USB port on the right side. The stated current input is 5 V / 1 A. This makes the detector practical to recharge in an office, laboratory, workshop or during technical work using compatible chargers and cables. The display also shows battery status, so the operator can check remaining autonomy before or during use.

The device also includes a reset button on the right side, indicated as a square hole, to be used with a suitable small tool. This function is useful if a restart or operational reset is needed. As with all electronic environmental measuring instruments, the device should be used according to the manual instructions, avoiding impacts, exposure to water, excessive dust or environmental conditions not compatible with the intended use.

The stated working conditions are -9 ... 55 °C with humidity below 90% RH. These data make the PCE-GA 8 suitable for many indoor and technical environments, but the user must always check that the measuring context is within the indicated limits. In extreme environments, temperatures outside the range, condensation, aggressive dust or interfering gases, the suitability of the instrument should be carefully evaluated and applicable safety procedures followed.

In practical applications, the PCE-GA 8 can be used to check technical rooms, enclosed environments, warehouses, laboratories, offices, classrooms, production areas, rooms with limited ventilation, locations where processes may change oxygen concentration or areas where a quick check before access is required. It is also useful for HSE technicians, maintenance operators, facility managers and safety managers who need to verify environmental conditions in a simple and immediate way.

For correct use, the detector should be positioned at a representative point in the environment being checked, avoiding covering the upper sensor or placing it too close to localised sources that could distort the reading. Before interpreting the value, it is advisable to wait for the measurement to stabilise and observe the trend on the display. If the device is moved from one environment to another, it is useful to allow temperature, humidity and sensor conditions to adapt to the new environment.

In professional environments, the PCE-GA 8 should be considered a monitoring support instrument and not an automatic substitute for safety procedures, fixed detection systems or mandatory technical assessments. When working in confined spaces, gas-related areas, risk zones or regulated environments, company procedures, applicable standards and safety manager instructions must be followed. The detector helps improve operator awareness but does not replace training and correct procedures.

The PCE-GA 8 is therefore a practical solution for users looking for a portable oxygen detector with a clear display, O2 measurement from 0 to 30%, temperature and humidity monitoring, data saving, rechargeable lithium battery and simple management through front and side buttons. The combination of compact design, immediate reading and multi-parameter monitoring makes it suitable for technicians, companies, laboratories and safety managers who need to quickly check air quality and environmental conditions.

PCE-GA 8 Gas Detector - Technical Specifications

Parameter Value
Relative humidity - Measuring range 0 ... 100 %
Relative humidity - Resolution 0,1 %
Relative humidity - Accuracy ±5 % R.H.
Oxygen - Measuring range 0 ... 30 % vol.
Oxygen - Resolution 0,1 % vol.
Oxygen - Accuracy ±0,3 % of measured value.
Temperature - Measuring range -9 ... 55 °C
Temperature - Resolution 1 °C
Temperature - Accuracy ±0,5 °C
Display type Colour TFT display
Display size 2,8 inches
Storage medium Internal memory
Storage capacity 100000 data records
Storage interval from 10 s
Storage interval up to 600 s
Interfaces Micro-USB
Operating time 8 h
Adjustable automatic shut-off 0 ... 1080 min.
Menu language English (GB), English
Device protection class IP20
Power supply 5 V DC
Battery 1 x 3,7 V internal
Battery capacity 3000 mAh
Operating conditions -9 ... 55 °C, 90 % R.H.
Storage conditions -9 ... 55 °C, 90 % R.H.
Dimensions (L x W x H) 180 x 76 x 31 mm
Weight 207 g

PCE-GA 8 Gas Detector - Delivery Contents

Quantity Description
1 x PCE-GA 8 gas detector
1 x USB-C cable
1 x User manual available in English, Italian
EAN Code:
4250348747648
Typology:
Gas detector
Brand:
PCE INSTRUMENTS