PCE Instruments PCE-OC 15 Frequency meter for reliable measurement of voltage, current, frequency, resistance, temperature and capacitance
(Incl. Tax: €118.22)
The PCE-OC 15 is a versatile frequency meter designed for reliable measurement of voltage, current, frequency, resistance, temperature, and capacitance. Its user-friendly interface and comprehensive measurement capabilities make it suitable for a wide range of electrical testing applications. The device is ideal for professionals seeking accurate and efficient measurement solutions in various settings.
This multifunction frequency meter combines the performance of an advanced digital multimeter with that of a portable oscilloscope, providing a complete solution for field electrical measurements. With a 10 MHz bandwidth and sampling rate up to 48 MSa/s, the instrument ensures accurate measurements of voltage, current, frequency, resistance, temperature and capacitance, plus diode test and continuity functions. The ability to instantly switch between multimeter and oscilloscope modes via the MODE button makes it an extremely versatile tool for technicians and maintenance personnel.
Technical specifications:
| Direct voltage DC | |
| Measurement range up to | 0 - 9,999 mV |
| Resolution | 0,001 mV |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 10 - 99,99 mV |
| Resolution | 0,01 mV |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 100 - 999,9 mV |
| Resolution | 0,1 mV |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 1 - 9,999 V |
| Resolution | 0,001 V |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 10 - 99,99 V |
| Resolution | 0,01 V |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 100 - 999,9 V |
| Resolution | 0,1 V |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 0 - 9999 µA |
| Resolution | 1 µA |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 10 - 99,99 mA |
| Resolution | 0,01 mA |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 100 - 999,9 mA |
| Resolution | 0,1 mA |
| Accuracy | ±(1 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 1 - 9,999 A |
| Resolution | 0,001 A |
| Accuracy | ±(1 % of Rd +3 digits) |
| Capacity | |
| Measurement range up to | 0 - 9,999 nF |
| Resolution | 0,001 nF |
| Accuracy | ±(5 % of Rd +20 digits) |
| Capacity | |
| Measurement range up to | 10 - 99,99 nF |
| Resolution | 0,01 nF |
| Accuracy | ±(2 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 100 - 999,9 nF |
| Resolution | 0,1 nF |
| Accuracy | ±(2 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 1 - 9,999 µF |
| Resolution | 0,001 µF |
| Accuracy | ±(2 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 10 - 99,99 µF |
| Resolution | 0,01 µF |
| Accuracy | ±(2 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 100 - 999,9 µF |
| Resolution | 0,1 µF |
| Accuracy | ±(5 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 1 - 9,999 mF |
| Resolution | 0,001 mF |
| Accuracy | ±(5 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 10 - 99,99 mF |
| Resolution | 0,01 mF |
| Accuracy | ±(5 % of Rd +5 digits) |
| AC voltage | |
| Measurement range up to | 0 - 9,999 mV |
| Resolution | 0,001 mV |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 - 1000 Hz |
| AC voltage | |
| Measurement range up to | 10 - 99,99 mV |
| Resolution | 0,01 mV |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 - 1000 Hz |
| AC voltage | |
| Measurement range up to | 100 - 999,9 mV |
| Resolution | 0,1 mV |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 - 1000 Hz |
| AC voltage | |
| Measurement range up to | 1 - 9,999 V |
| Resolution | 0,001 V |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 - 1000 Hz |
| AC voltage | |
| Measurement range up to | 10 - 99,99 V |
| Resolution | 0,01 V |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 - 1000 Hz |
| AC voltage | |
| Measurement range up to | 100 - 750 V |
| Resolution | 0,1 V |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 - 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 0 - 9999 µA |
| Resolution | 1 µA |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 - 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 10 - 99,99 mA |
| Resolution | 0,01 mA |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 - 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 100 - 999,9 mA |
| Resolution | 0,1 mA |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Frequency range | 40 - 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 1 - 9,999 A |
| Resolution | 0,001 A |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Frequency range | 40 - 1000 Hz |
| Resistance | |
| Measurement range up to | 0 - 99,99 Ω |
| Resolution | 0,01 Ω |
| Accuracy | ±(1 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 100 - 999,9 Ω |
| Resolution | 0,1 Ω |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 1000 Ω - 9,999 kΩ |
| Resolution | 0,001 kΩ |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 10 - 99,99 kΩ |
| Resolution | 0,01 kΩ |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 100 - 999,9 kΩ |
| Resolution | 0,1 kΩ |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 1000 kΩ - 9,999 M Ω |
| Resolution | 0,001 mΩ |
| Accuracy | ±(1.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 10 - 99,99 M Ω |
| Resolution | 0,01 mΩ |
| Accuracy | ±(3 % of Rd +5 digits) |
| Frequency | |
| Measurement range up to | 0 - 99,99 Hz |
| Resolution | 0,01 Hz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 100 - 999,9 Hz |
| Resolution | 0,1 Hz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 1000 Hz - 9,999 kHz |
| Resolution | 0,001 kHz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 10 - 99,99 kHz |
| Resolution | 0,01 kHz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 100 - 999,9 kHz |
| Resolution | 0,1 kHz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Temperature | |
| Measurement range up to | -20 - +1000 °C |
| Resolution | 1 °C |
| Accuracy | ±(2.5 % of Rd +5 digits) |
| Temperature | |
| Measurement range up to | -4 - +1832 °F |
| Resolution | 1 °F |
| Accuracy | ±(2.5 % of Rd +5 digits) |
| Oscilloscope specifications | |
| Number of channels | 1 |
| Measuring functions | Period, Frequency, Peak-peak, MAX, MIN, RMS value |
| Sampling rate | 48 MSa/s |
| Input impedance | 1 M Ω |
| Probe factors | X1, X10 |
| Max. input voltage | 150 V |
| Adjustable sampling rate | 1.5 Sa/s - 48 MSa/s |
| Time base | 100 ns/div - 20 s/div |
| Accuracy | 20 ppm |
| Vertical sensitivity | 20 mV/div - 10 V/div |
| Rise time | 10 ns |
| DC gain accuracy | ±3 % |
| General technical data | |
| Display type | LCD |
| Display size | 2,76 Inch |
| Measuring rate | 3 Hz |
| Storage medium | Internal memory |
| Storage capacity | 15 MB |
| Memory information | Screenshot on keystroke |
| Interface | USB-C, BNC |
| Automatic power-off from-to | 15 - 120 min. |
| Automatic power-off can be deactivated | Yes |
| Safety standard | CAT III 600 V, CAT II 1000 V |
| Fuse(s) | Microfuse 10 A |
| Trigger input | Mode: auto, normal, single Edge: rising, falling |
| Menu language | English, Chinese, English (GB) |
| Protection class (device) | IP20 |
| Power supply | 100 - 240 V AC | 50/60 Hz |
| Weight | 352 g |
| Operating conditions | 0 - 40 °C , 0 - 75 % RH |
| Storage conditions | -20 - 60 °C , 0 - 80 % RH |
| (Rechargeable) battery | 1 x 3,7 V 18650 , lithium |
| Capacity | 2000 mAh |
| Dimensions ( L x W x H ) | 175 x 90 x 40 mm |
Powered by a long-life USB-C rechargeable battery, the device features an LCD display with four adjustable brightness levels and customizable timeout settings. The waveform storage function, exportable as images to PC, adds diagnostic value, while three-times-per-second measurement updates ensure always current data. Automatic range selection and control ergonomics make it the ideal tool for quick interventions in workshops or plants, where precision and versatility are essential.
Features:
- multimeter with oscilloscope functions
- bandwidth 10 MHz
- sampling rate up to 48 MSa/s
- LC display with 4 brightness levels
- auto measurement range selection
- USB-C interface
Delivery scope:
1 x Oscilloscope PCE-OC 15
1 x set of test leads
1 x Oscilloscope probe
1 x temperature sensor
1 x USB-C cable
1 x user manual
1 x probe accessories
- EAN Code:
- 4250348736116
- Typology:
- Multifunctional
- Brand: