PCE Instruments PCE-895-ICA Non-contact temperature meter with dual laser, rapid measurement up to 1,600°C, emissivity setting, USB, MicroSD, backlit LCD display
In stock
SKU
PCE-895-ICA
€771.05
(Incl. Tax: €940.68)
(Incl. Tax: €940.68)
PCE-895-ICA Temperature Meter for non-contact surface measurements with dual laser for precise point indication. It offers a rapid response time, an emissivity setting adjustable between 0.10 and 1.0, and a measurement range from -35 to 1,600°C. Includes USB and MicroSD card slot for data recording and download. The backlit LCD display and alarm function complete the features. Ideal for food control, hygiene, road construction, distribution cabinets, HVAC, production, and engines.
Technical specifications:
| Infrared | |
| Measuring range | -35 ... 1600°C / -31 ... 2912°F |
| Measuring accuracy (at 23 ... 25°C ambient temperature) | -35 ... 0°C / 0°F: ± 2°C / 3.6°F + 0.05*TObj 0 ... 1600°C: ± 2% of rdg. or ± 2°C / 3.6°F |
| Resolution | 1°C / 1.8°F at 1000 .... 1600°C / 1832 ... 2912°F |
| Thermocouple | |
| Measuring range | Type K: -64 ... 1400°C / -83 ... 2552°F |
| Measuring accuracy (at 23 ... 25°C ambient temperature) | ± 1% of rdg. or ± 1°C / 1.8°F |
| Resolution | 0.1°C / 0.18°F at -64 ... 999.9°C / -83.2 ... 1831.8°F |
| Emissivity | Adjustable 0.10 ... 1.0 |
| Spectral range | 8 ... 14 µm |
| Response time | 1 s |
| Optical resolution / measurement spot ratio | 60:1 |
| Storage | Internal: 24 memory points External (micro-SD card): max. 8 GB supported |
| Interface | USB |
| Display | LCD illuminated |
| Power supply | 2 x 1.5V AA batteries |
| Operating time | Typical: 14 h Continuous: 10 h |
| Operating conditions | 0 ... 50°C / 32 ... 122°F |
| Weight | ca. 400 g / 14.1 oz |
| Dimensions | 203 x 176 x 89 mm / 7.9 x 6.9 x 3.5 in |
The PCE-895-ICA temperature meter with dual laser represents an advanced solution for non-contact surface temperature measurement. This instrument is designed to provide precise and immediate readings thanks to its two laser pointers, which clearly indicate the exact measurement point. With a measurement range from -35 to 1,600°C, the PCE-895 is suitable for a wide range of applications, from simple maintenance to more complex industrial analyses.
The PCE-895-ICA temperature meter is equipped with a backlit LCD display that ensures clear data visibility even in poorly lit environments. Additionally, the device allows for an emissivity setting within a range of 0.10 to 1.0. This feature is particularly useful for improving measurement accuracy on various surfaces, adapting to the emissivity variations of materials.
A distinctive feature of this meter is its ability to record data via USB interface and MicroSD card slot. The MicroSD card allows for extended recording of surface temperatures, facilitating data storage and analysis. This function is essential for monitoring the temperatures of machinery, plants, and other equipment, enabling detailed analysis and optimal resource management.
The integrated alarm function in the PCE-895 alerts the user when temperatures exceed predefined values, offering an additional level of control and safety. This is especially useful in industrial contexts where maintaining operational conditions within specific parameters is crucial to ensure process efficiency and safety.
The applications of the dual laser temperature meter are broad and diverse. In the food industry, it is used to monitor and ensure that temperatures are kept within safe limits, contributing to food safety. In the hygiene sector, the device is used to ensure that surfaces and equipment are maintained at appropriate temperatures to prevent contamination. In road construction and distribution cabinet management, the PCE-895 provides precise measurements that help ensure infrastructure quality and reliability.
In the field of HVAC technology, the meter is used to monitor the temperatures of heating and cooling systems, while in production and engine temperature measurement, it helps ensure that processes and components operate within required specifications.
With its combination of precision, versatility, and ease of use, the PCE-895 temperature meter proves to be an essential tool for engineers, technicians, and industry professionals, offering reliable and detailed support for temperature control and management across a variety of industrial and scientific applications.
Caratteristichs:
- Non-contact temperature measurement
- 60:1 optics
- Temperature measurement up to 1600°C / 2912°F
- Compact cross laser thermometer
- Double laser shows the spot diameter
- Adjustable emissivity
- Adjustable emissivity
- Alarm function
- Incl. ISO Calibration certificate
Typical applications of Dual Laser Infrared Thermometer PCE-895
- Food inspection
- Hygiene tests
- Road construction
- Switch cabinet monitoring
- Heating and air conditioning technology
- Production monitoring
- Temperature measurement on motors
***ATTENTION*** This temperature sensors are designed for industrial and laboratory surface temperature measurement ONLY. They are not designed or certified for body temperature measurement or for medical use.
Delivery scope:
1 x Infrared Thermometer PCE-895-ICA
1 x USB Cable
1 x Micro SD Card 8 GB
1 x PC Software
2 x 1.5V AA Batteries
1 x Thermocouple Type K ( 0 ... 250°C / 32 ... 482°F)
1 x User manual
1 x USB Cable
1 x Micro SD Card 8 GB
1 x PC Software
2 x 1.5V AA Batteries
1 x Thermocouple Type K ( 0 ... 250°C / 32 ... 482°F)
1 x User manual
1 x ISO Calibration Certificate
Calibration certificates are issued specifically for the customer and are excluded from the right of return.
- EAN Code:
- 4250348728180
- Typology:
- Pyrometers
- Brand:
- PCE INSTRUMENTS
- Resolution (mm):
- 0.1 °C
- Temperature:
- -64°C +1.400 ºC